Using Digitizers With RevWorks
Starting - Starting Gage 2000a Digitizers
Starting Gage 2000a Digitizers Gage 2000a digitizers do not require any special setup before starting. To Start a Gage 2000a Digitizer Make sure that the device is securely mounted to the working surface or tripod. Note: See your Gage 2000a ...
Starting - Starting FARO Serial Digitizers
Starting FARO Serial Digitizers FARO digitizers do not require any special setup before starting. To Start a FARO Serial Interface Digitizer Make sure that the device is securely mounted to the working surface or apparatus and that it is properly ...
Starting - Starting FARO USB Digitizers
Starting FARO USB Digitizers FARO USB portable CMMs do not require any special setup before starting. Once communication is first attempted an arm start-up calibration dialog is presented that displays a generic image of an arm and red arrows ...
Starting - Starting 3DCreator Digitizers
Starting 3DCreator Digitizers When starting 3DCreator digitizers you must first make sure that the components to be used are properly connected, the article to be digitized is placed within the working area of the camera sensor array, and that the ...
Starting - Starting Romer Digitizers
Starting Romer Digitizers Romer portable CMMs do not require any special setup before starting. Once communication is first attempted an arm start-up calibration dialog is presented that displays a set of progress bars indicating which arm joints ...
Starting - Starting MicroScribe Digitizers
Starting MicroScribe Digitizers The MicroScribe Calibration Wizard also manages homing of your MicroScribe device and leads you through any necessary steps. In the case of MicroScribe 3D series digitizers, make sure that the device is seated in the ...
Starting - Starting Digitizers
Starting Digitizers Digitizers have different startup procedures. Remember, when you first attempt to collect data, you may notice a delay time in processing speed. That is because RevWorks executes a connection procedure that secures data ...
Configuring - Configuring RevWorks for Gage 2000a Digitizers
Configuring RevWorks for Gage 2000a Digitizers The Gage 2000a digitizer requires no hardware configuration for use. When RevWorks first attempts to communicate with a Gage 2000a digitizer, RevWorks automatically initializes the serial baud rate and ...
Configuring - Configuring RevWorks for FARO Serial Digitizers
Configuring RevWorks for FARO Serial Digitizers The FARO 3D digitizer requires no hardware configuration for use. When RevWorks first attempts to communicate with a FARO digitizer, RevWorks automatically initializes the serial baud rate and begins ...
Configuring - Configuring FARO USB Arm Characteristics
Configuring FARO USB Arm Characteristics Several interface characteristics for the FARO USB arm can be adjusted to better suit your personal preferences including: The use of stress stops and their sensitivity Mouse movement and button assignment ...
Configuring - Configuring RevWorks for FARO USB Digitizers
Configuring RevWorks for FARO USB Digitizers FARO USB digitizers require no hardware configuration for use. When RevWorks first attempts to communicate with a FARO USB device, RevWorks automatically initializes the communications parameters to ...
Configuring - Configuring HyperTerminal for Communication with the 3DCreator Interface Controller
Configuring HyperTerminal for Communication with the 3DCreator Interface Controller The Windows HyperTerminal terminal emulation program is suitable for doing maintenance communication with the 3DCreator interface controller. This task leads you ...
Configuring - Adding Tools to the 3DCreator Interface Controller
Adding Tools to the 3DCreator Interface Controller From time to time you may want to update or add to the tools stored in the 3DCreator controller box. This task may be accomplished through the use of HyperTerminal or a similar terminal emulation ...
Configuring - Configuring RevWorks for 3DCreator Digitizers
Configuring RevWorks for 3DCreator Digitizers The 3DCreator may require some hardware configuration before first use in order to properly identify the probes and Dynamic Reference Frames that are to be used. The actual configuration of RevWorks for ...
Configuring - Accessing Romer Tools
Accessing Romer Tools RevWorks provides convenient direct access to many useful Romer WinRDS configuration options and special function tools. These options allow you to access several of the features of WinRDS without leaving RevWorks for ...
Configuring - Configuring Romer Sounds
Configuring Romer Sounds In addition to the standard RevWorks sounds, or instead of, you can choose to have the Romer device generate sounds directly through its internal speaker. This option is useful in situations where the digitizer is separated ...
Configuring - Configuring RevWorks for Romer Digitizers
Configuring RevWorks for Romer Digitizers Romer portable CMMs require no hardware configuration for use. When RevWorks first attempts to communicate with a Romer device, RevWorks automatically initializes the communications parameters to default ...
Configuring - Configuring RevWorks for MicrScribe Digitizers
Configuring RevWorks for MicroScribe Digitizers The MicroScribe digitizer requires no hardware configuration in order to use. However, for 3D series arms you must make sure that the machine is in its proper "home" position before turning it on. ...
Configuring - Configuring RevWorks to Work With Digitizers
Configuring RevWorks to Work With Digitizers RevWorks requires configuration options for each digitizing device that you use. At any time, you can change configuration options for digitizers and RevWorks communication parameters. All changes take ...
Connecting - Connecting Gage 2000a Digitizers
Connecting Gage 2000a Digitizers RevWorks is completely compatible with Gage 2000a articulated arm digitizers. Before connecting a Gage 2000a digitizer, the device must be properly secured for use. For specific instructions on how to properly mount ...
Connecting - Connecting FARO Serial Digitizers
Connecting FARO Serial Digitizers RevWorks is completely compatible with FARO Technologies articulated arm digitizers. Before connecting a FARO digitizer, the device must be properly secured for use. For specific instructions on how to properly mount ...
Connecting - Connecting FARO USB Digitizers
Connecting FARO USB Digitizers RevWorks is completely compatible with the newer series FARO articulated arm digitizers employing USB communications. Before connecting a FARO USB digitizer, the device must be properly secured for use. For specific ...
Connecting - Connecting 3DCreator Digitizers
Connecting 3DCreator Digitizers RevWorks is completely compatible with the 3DCreator series of non-tethered digitizers. Before connecting a 3DCreator digitizer, the device components must be properly connected and the camera array secured for use. ...
Connecting - Connecting Romer Digitizers
Connecting Romer Digitizers RevWorks is completely compatible with the entire family of Romer articulated arm digitizers. Before connecting a Romer digitizer, the device must be properly secured for use. There are a variety of mechanisms available ...
Connecting - Connecting MicroScribe Digitizers
Connecting MicroScribe Digitizers RevWorks is completely compatible with the most current M, G and older 3D series MicroScribe articulated arm digitizers. Each series of MicroScribe comes in a variety of models characterized by two distinct working ...
Connecting - Connecting Digitizers
Connecting Digitizers Before you can use a digitizing device with RevWorks, you must install RevWorks, install any software device drivers required by your digitizing device and connect the device to your computer. If you have a digitizer that uses ...
About Gage 2000a Digitizers
About Gage 2000a Digitizers Gage 2000a digitizers are rugged, articulated portable measurement arms. The complete Gage 2000a product line features several models ranging in size, accuracy, and freedom-of-movement configurations. Gage 2000a arms ...
About FARO Digitizers
About FARO Digitizers FARO digitizers are rugged, articulated portable measurement arms. The complete FARO product line features several models ranging in size, accuracy, and freedom-of-movement configurations. FARO arms support probe exchange. ...
About 3DCreator Digitizers
About 3DCreator Digitizers 3DCreator digitizers are distinctive in that they offer a unique non-tethered stylus and a large working volume at a lower price than other large-volume digitizers. The non-tethered stylus provides many advantages over ...
About Romer Digitizers
About Romer Digitizers Romer digitizers are rugged, articulated portable measurement arms. The complete Romer product line features several models ranging in size, accuracy, and freedom-of-movement configurations. Romer arms support reproducible ...
About MicroScribe Digitizers
About MicroScribe Digitizers MicroScribe digitizers are compact, articulated desktop measurement arms. There are four series of MicroScribe arms: the older 3D series that communicates via a serial interface only; the G and i series that ...
About Digitizers
About Digitizers Before you can use a digitizing device, you must properly connect the digitizer to your computer and configure RevWorks to communicate with the digitizer. Each make of digitizer has specific requirements for setup and ...