Starting - Starting 3DCreator Digitizers

Starting - Starting 3DCreator Digitizers

Starting 3DCreator Digitizers

 

When starting 3DCreator digitizers you must first make sure that the components to be used are properly connected, the article to be digitized is placed within the working area of the camera sensor array, and that the probes and DRFs to be used can be positioned in useful proximity of the object and that there is an open line-of-sight between the tools and the camera sensor array.

To Start a 3DCreator Digitizer

  1. Make sure that the 3DCreator camera array is securely mounted to the working surface or support apparatus and that it is properly connected.

    Note: See your 3DCreator hardware documentation for specific instructions on how to properly mount the camera sensor array.

  1. Connect the desired tethered tools to the available ports on the front of the 3DCreater interface controller.

    Note: The 3DCreator interface controller ports to which you connect specific tools must be configured in Probe Manager before you can begin collecting data.

  1. Power on the 3DCreator interface controller.

After a few seconds you hear a single beep followed by an ascending series of tones, about 20 seconds later, to signal the successful start-up of the 3DCreator interface controller.

  1. Select on the RevWorks toolbar, or
    select
    Probe Manager from the RevWorks menu in SolidWorks
    and choose the probe you plan to use.

    Note: If you are using a non-tethered stylus, be sure to turn the stylus on before proceeding to data collection. When not actively collecting data you may wish to turn the stylus off to conserve battery life.

  1. From the RevWorks toolbar or menu, select a feature to digitize (e.g.: line, circle, arc, etc.).

RevWorks automatically connects to your 3DCreator digitizer.

    • Related Articles

    • Starting - Starting FARO Serial Digitizers

      Starting FARO Serial Digitizers   FARO digitizers do not require any special setup before starting. To Start a FARO Serial Interface Digitizer Make sure that the device is securely mounted to the working surface or apparatus and that it is properly ...
    • Starting - Starting FARO USB Digitizers

      Starting FARO USB Digitizers   FARO USB portable CMMs do not require any special setup before starting. Once communication is first attempted an arm start-up calibration dialog is presented that displays a generic image of an arm and red arrows ...
    • Starting - Starting Romer Digitizers

      Starting Romer Digitizers   Romer portable CMMs do not require any special setup before starting. Once communication is first attempted an arm start-up calibration dialog is presented that displays a set of progress bars indicating which arm joints ...
    • Starting - Starting Gage 2000a Digitizers

      Starting Gage 2000a Digitizers   Gage 2000a digitizers do not require any special setup before starting. To Start a Gage 2000a Digitizer Make sure that the device is securely mounted to the working surface or tripod. Note: See your Gage 2000a ...
    • Enabling Probe Manager

      Enabling Probe Manager   When you enable Probe Manager, you can define and use multiple probes while digitizing a part. RevWorks automatically compensates data that you collect with ball probes to maintain data alignment. Note: Probe Manager is only ...